Grounding system design with protective relaying bookmark

A system of ground clamps, ferrules, cluster bars and cables designed and suitable for carrying fault current as specified in astm f855. This is the fourth generation hrg system from post glover and is the premier digital high resistance pulsing grounding system available. Philosophy on design objectives and criteria equipment and recording considerations. To identify any terminal which is intended on your mark for protection against electrical shock in case of a fault, or the terminal of a protective earth ground electrode. Grounded system refers to a system where a conductor is grounded and is intended to or may carry current in the normal operation. A transformer is always considered a separately derived system. Advanced techniques for analysing operation of protective relays and related interactions with the power system are discussed.

Electrical circuit or system grounding electrical equipment grounding electrical system grounding one conductor of the circuit is intentionally grounded to earth protects circuit from lightning, or other high voltage contact equipment grounding all metal. M electrical cathodic protection issues in large generating. A marginal ground system, however, will cause problems on a regular basis. Multiple accurate soil resistivity readings should be done at various depths usually 3 depths across the. Weve expanded our partnership post glover now has an expanded partnership with rockwell automation to include encompass asiapacific. In this article, you will be able to cover the different electric protection methods, system and devices, grading and protection, overhead lines protection, power system protection, cables feeder protection, transformer protection, motor protection,generator protection, capacitor banks protection, bus bar protection, voltage.

Electrical protection systems, devices and units electrical. Lewis blackburn, the fourth edition retains the core concepts at the heart of power system analysis. Equipment grounding conductor acts as a safeguard against insulation failure or faults in the other circuit conductors. Mcgrawhills nec 2014 grounding and earthing handbook. Inc is a unique company offering a wide range of experience and education in the area of power system operations, design, consultation and studies. Technique for grounding system design in distribution substation. The term ungrounded system is actually a misnomer, since every system is grounded through its inherent.

Introduction the attention given to the design and installation of a facility ground system is a key element in the dayto day reliability of the plant. Protection systems contents description page general information 2 checklist for g. Understanding the importance of electrical grounding nec 250. Modern grounding switches allow personnel to perform maintenance grounding with switchgear completely enclosed. Statistically, 9095% of all system shortcircuits are ground faults so this is an important topic. Corrosionpedia cathodic protection of earthed tank farms. A welldesigned and installed ground network is invisible to the engineering staff. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous groundingthere are two kinds of grounding. Protective relaying philosophy and design standards. The codes shown are examples only and may not be current or accurate for your.

A sturdy canvas carrying bag is supplied to ensure the operating components of the grounding kit remain clean and ready for service. Principles of electrical grounding john pfeiffer, p. Mcgrawhills national electrical code 2014 grounding and earthing handbook fully addresses the abovegrade grounding and belowgrade earthing issues related to article 250 of the 2014 national electrical code. By extending emtps capabilities, the response of a grounding system to transient or other phenomena, can be computed using transmission line models 1,7. Protective relaying philosophy and design guidelines pjm. The question, however, is how these systems can be made to be compatible with each other in order to ensure effective operation. Maintenance grounding is a proven method for protecting electrical workers during mediumvoltage switchgear maintenance. This system is a remote one, where the groundbed, or anode, is placed at a remote place, which may be at any corner of the tank farm, and is used to cathodically protect all buried metallic structures in the tank farm including the earthing grid for this system, all metallic structures must be bonded, either mechanically or. This practical guide features indepth discussions of each of the codes requirements, section by section, along with clear. Advances in technology, such as the microprocessor and fiber optics, will continue to produce re. What would make a generator a separately derived system is if a transfer switch also switched the grounded conductor neutral.

Substation automation, system design and implementation apply theory to real system examples communication theory and practice on microprocessor. Sep 10, 2015 introduction the attention given to the design and installation of a facility ground system is a key element in the dayto day reliability of the plant. Continuing in the bestselling tradition of the previous editions by the late j. Temporary protective grounding equipment installed in a manner that bonds the ground source and the cables phase conductor and concentric neutral. Multiple accurate soil resistivity readings should be done at various depths usually 3 depths across the site.

Electrical circuit or system grounding electrical equipment grounding electrical system grounding one conductor of the circuit is intentionally grounded to earth protects circuit from lightning, or other high voltage contact. Grounddistancerelay connections, 360 groundfault neutralizer, effect on line relaying, 321 to mitigate the effect of a fault, 2 grounding protective relay for trans former protection, 263 ground preference, 91, 108 ground resistance, 303 groundingtranaformer protection, 268 hsrmoniccurrent restraint, for distance relays. All of the power sources mentioned above except d are magneticallyoperated devices with windings. Pdf grounding system design in electrical substation. The main purpose of this work is the development of an optimization model for the design of the grounding grid in electrical substations. Design and application considerations for each problem area are given to aid in setting the relay elements correctly. Earthing systems design steps part one electrical knowhow. Apr 03, 20 the path to ground from circuits, equipment, and enclosures shall be permanent and continuous groundingthere are two kinds of grounding. Delphi grounding systems offer easy, onestep preassembly of multiple wiring harnesses to one centrally located grounding base. Presented at the 69th annual georgia tech protective relaying conference atlanta, georgia april 29may 1, 2015 previous revised edition released october 2014. Instructions ground protection systems ge industrial. The neutral on a wye system is a prime example of a grounded conductor. Grounding analysis is performed by considering the metal parts. Shields is a comprehensive study guide for the design of industrial and commercial electrical power systems as dictated by neutral grounding and groundfault protection practices.

The purpose of this project is to give indept insight on resonant grounding methods, sources of ground current, ground current flow in the power system, and how each impacts protective relaying with a ground fault neutralizer used in resonant grounding. Protective devices associated with a high resistance system allows the system to continue working with the presence of a ground fault and send an alarm instead of tripping and open the associated protection. Resistance grounding in an electrical system is defined as the use of a resistor as a grounding path between the neutral point of transformer or generator and the earth ground. When mated with similarly rated products, the grounding kit operating components provide a fullyshielded, submersible, separable grounding system. The problem is formulated as a mixedinteger linear. An ungrounded system is a system where there is no intentional connection of the system to ground. It describes the case of a large electrical generating station with a bare copper grounding grid, typical of late1960s construction practices. Shields is a comprehensive study guide for the design of industrial and commercial electrical power systems as dictated by neutralgrounding and groundfault protection practices. Industrial power system grounding design handbook by j.

There are two methods to accomplish this system of grounding, namely the low resistance grounding and high resistance grounding. When applied properly, it eliminates dangerous differences in electric potential and can redirect harmful current during events such as. Primary and backup relay systems primary schemes are generally high speed schemes operate speed 1 cycle backup schemes can also be high speed but dont have to be. To understand the system voltage relationships with respect to system grounding, it must be recognized that there. The types of system grounding normally used in industrial and commercial power systems are. Different types of protection for electrical systems and networks. The overview of grounding system can protect damage from fault such as can save a human life and power system equipment. New approaches for maintenance grounding in mv switchgear. System conditions dictate if this scheme has to be as fast as the primary scheme pjm2014 17 114. Facility and equipment grounding to enhance equipment.

This, combined with the fundamental concepts and applications of electric power systems protection make this book a good reference for anyone with interest in protection, automation and control. The practices used in groundfault protection are described in a later section of this guide. A conductor used as an equipment grounding conductor shall be identifiable and distinguishable from all other conductors identification of conductors grounded conductor. The main objective of this paper is guide the first step for someone who attends to design of grounding system before study in details later. This is a discussion of the basic principles behind grounding systems and how grounding is related to safety and the effective operation of circuit protection devices such as fuses and circuit breakers. Protective relays provide the brains to sense trouble, but they are not able to open and isolate the problem area of power system. Principles and applications, third edition power engineering willis hardcover technological advances and structural changes within the electric utility industry mandate that protection engineers develop a solid understanding of the related new technologies as well as of power system operations and economics in order. Power cable systems grounding tutorials and basics. Relays 5 to 12 test diagrams for systems with integral g. Industrial power system grounding design handbook john. Technique for grounding system design in distribution.

A safe and costefficient grounding system design of a 3 mwp photovoltaic power station according to ieee std 802000 is presented. Without grounding, shields would operate at a potential considerably above ground. Principles and applications has been the goto text for gaining proficiency in the technological fundamentals of power system protection. While most systems today are limited by the number of parts you can preassemble, this simple, manual process allows the assembly of multiple components limited only by the length of the grounding bolt. A typical scheme for detecting a ground fault in a high resistance grounding system is. Lewis blackburn, the fourth edition retains the core concepts at the heart of power system. Not an energized conductor under normal conditions. Testing 3 test methods 3,4 test equipment 4 notes on testing 4 test diagrams for systems with g. Safe grounding system design for a photovoltaic power station. Accordingly, the design of such protection systems must.

Apr 03, 20 grounded conductor is an energized circuit conductor that is connected to earth through the system ground commonly referred to as the neutral grounding conductors. We provide extensive services from planning studies, design and construction, to periodic testing and maintenance. Targeting the latest microprocessor technologies for more sophisticated applications in the field of power system short circuit detection, this revised and updated source imparts fundamental concepts and breakthrough science for the isolation of faulty equipment and minimization of damage in power system apparatus. The various protocols and network topologies used for protective relaying. A residually connected ground relay is widely used to protect mediumvoltage systems. Two models can be used aby dividing the system in a number of segments, each. Ul 467 grounding and bonding equipment standards catalog. Apr 19, 2018 cathodic protection of earthed tank farms in order to overcome corrosion and safety problems in tank farms, both cathodic protection and grounding systems need to be applied. A comprehensive soil resistivity survey is key to creating an effective earthing system, as inadequate or erroneous soil resistivity readings are likely to result in a flawed design. The actual ground current is measured by cts that are interconnected in such a way that the ground relay responds to a current proportional to the groundfault current. System grounding, or the intentional connection of a phase or neutral conductor to earth. Sep 09, 2003 targeting the latest microprocessor technologies for more sophisticated applications in the field of power system short circuit detection, this revised and updated source imparts fundamental concepts and breakthrough science for the isolation of faulty equipment and minimization of damage in power system apparatus. Ungrounded systems this system grounding arrangement is at the other end of the spectrum from solidlygrounded systems. The second part is concerned mainly with power system relaying communication.

1018 273 488 210 650 1003 996 945 1346 29 1537 316 529 954 1547 102 1371 875 417 1164 638 566 775 71 1357 838 243 435 394 882 29 208